[1] D. Westphalen, R. Zogg, A. Varon and M. Foran, "Energy savings potential for commercial refrigeration equipment," Final Report Prepared for Building Equipment Division Office of Building Technologies. U.S, Department of Energy, Cambridge, 1996.
[2] R. Faramarzi, "Efficient display case refrigeration," ASHRAE Journal, vol. 41, no. 11, pp. 46-52, 1999.
[3] روی جی. دوسات، اصول تبرید: طراحی و محاسبات سیستمهای سردکننده، اصغر حاج سقطی، انتشارات دانشگاه علم و صنعت ایران، 1392
[4] F. Billard and J. L. Dupont, "Industry as a partner for sustainable development- Refrigeration," Final Report Prepared for UNEP - United Nations Environment Programme, Paris, France, 2002.
[5] F. Alamdari, "Air curtains: commercial applications, Application Guide, BSRIA," BSRIA, 1997.
[6] D. Stribling, "Investigation into the design and optimisation of multideck refrigerated display cases," Ph.D. Thesis, Brunel University, 1997.
[7] U. Lindberg, M. Axell and P. Fahlén, "Vertical display cabinets without and with doors–a comparison of measurements in a laboratory and in a supermarket," in Sustainability and the Cold Chain, Cambridge, 2010.
[8] Cao Z., Han H. and Gu B., A novel optimization strategy for the design of air curtains for open vertical refrigerated display cases, Appl. Therm. Eng. 31 (2011) 3098–3105.
[9] H. Navaz, B. Henderson, R. Faramarzi, A. Pourmovahed and F. Taugwalder, "Jet entrainment rate in air curtain of open refrigerated display cases," International Journal of Refrigeration, vol. 28, no. 2, pp. 267-275, 2005.
[10] B. Fricke and B. Becker, "Comparison of Vertical Display Cases: Energy and Productivity Impacts of Glass Doors Versus Open Vertical Display Cases," Kansas City, 2011.
[11] P. Gaspar, L. C. Goncalves and R. Pitarma, " Experimental analysis of the thermal
entrainment factor of air curtains in vertical open display cabinets for different ambient air
conditions," Applied Thermal Engineering, vol. 31, pp. 961-969, 2011.
[12] J. Sun, K. Tsamos and S. Tassou, "CFD comparisons of open-type refrigerated display cabinets with/without air guiding strips," Energy Procedia, vol. 123, pp. 54-61, 2017.
[13] P. Yuan, Q. Zeng, Z. Lei, Y. Wu, Y. Lu and C. Hu, "Experimental and numerical study of heat transfer and flow characteristics with different placement of the multi-deck display cabinet in supermarket, " Open Physics, vol. 19, no. 1, pp. 256-265, 2021.
[14] N. Chaomuang, D. Flick, A. Denis and O. Laguerre, "Experimental and numerical characterization of airflow in a closed refrigerated display cabinet using PIV and CFD techniques," International Journal of Refrigeration, vol. 111, pp. 168-177, March 2020.
[15] R. H. Howell, "Effects of store relative humidity on refrigerated display case," ASHRAE Trans, vol. 99, p. 667–678, 1993.
[16] R. Sweetser, "Supermarket relative humidity & display-case performance (2000)," Heating, Piping and Air Conditioning Engineering, vol. 72, p. 38–45, 2000.
[17] T. Vengalis, and V. Mokšin, "Experimental and Numerical Study of the Performance of an Open-Type Multi-Deck Refrigerated Cabinet with Single and Dual Air Curtain," Applied Science 2023, 13, 9080.
[18] S. Huang, Q. Chen, G. Liu, J. Liu, G. Yan, X. Hu, H. Ma, "Performance improvement for an open refrigerated display cabinet by limited coverage on the air curtain opening," International Journal of Refrigeration, 2024, 158, pp. 111-123.
[19] S. Liu, S. Zhang, X. Li, X. Hu, Q. Wang, "Technical feasibility study of open refrigerated display cabinet with independent air curtain," Thermal Science and Engineering Progress 2024, 53, 102723.
[20] مدارک فنی شرکت صنایع برودتی انجماد سیستم غرب. https://enjemadsystem.com/
[21] "COMPRESSOR TECHNICAL DATA," UPDATE: 27 March 2007, https://www. embraco.com/en/products.
[22] E. Hajidavalloo, "Application of evaporative cooling on the condenser of window-air-conditioner," Applied Thermal Engineering, 2007, 27 pp. 1937–1943.
[23] Y. Chen and X. Yuan, "Experimental study of the performance of single-band air curtains for a multi-deck refrigerated display cabinet," Journal of Food Engineering, vol. 69, no. 3, pp. 261-267, August 2005.
[24] H. Navaz, B. Henderson, R. Faramarzi, A. Pourmovahed and F. Taugwalder, "Jet entrainment rate in air curtain of open refrigerated display cases," International Journal of Refrigeration, vol. 28, no. 2, pp. 267-275, 2005.
[25] P. D’Agaro, G. Cortella and G. Croce, "Two- and three-dimensional CFD applied to vertical display cabinets simulationSimulation des meubles frigorifiques de vente verticaux à l'aide d'analyse par dynamique des fluids numérisée bi- et trideimensionnelle," International Journal of Refrigeration, vol. 29, no. 2, pp. 178-190, March 2006.
[26] K. Yu, G. Ding and T. Chen, "A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet," Applied Thermal Engineering, vol. 29, pp. 2904-2913, 2009.
[27] F. C. Hayes and W. F. Stoecker, "Design data for air curtains," ASHRAE Transactions, 1969.
[28] Thechnical documents of Testo company, https://www.testo.com.
[29] Thechnical documents of Mastech company, https://www.mastech-group.com/global/en.
[30] Thechnical documents of Siemens company, Electronic phase-angle meter, https://www.siemens.com/global/en.
[31] A. A. Al-Sahhaf, "Performance improvement for an open refrigerated display cabinet by limited coverage on the air curtain opening," PhD thesis, 2013, Brunel University.