Search published articles
Showing 2 results for Jaafarian
M.e. Kazemian, A.h. Kazemian, S.m. Jaafarian,
Volume 19, Issue 12 (December 2019)
Abstract
In this paper, the effect of the Gurney flap parameters such as the angle of attack, Reynolds number, angle and height of the flap and its location from the escape edge on the lift coefficient of a symmetric airfoil is considered with the help of simulation in computational fluid dynamic software of Fluent. The turbulence model k-ε is used for the two-dimensional domain. Also, the value of the lift coefficient is introduced as a function of effective parameters by the design of experiment (DOE) method and using the backward elimination regression model which is a statistical method for selecting the model and estimated error terms. The value of the airfoil lift coefficient can be determined and predicted by the obtained function. The numerical values derived from the function of the lift coefficient resulted from the design of experiment method are in good agreement with other valid papers. The results show that at the constant attack angle by increasing Gurney flap height, lift coefficient increase. On the other hand, at the constant height of the Gurney flap, this coefficient decreases with increasing angle of attack. Moreover, the lift coefficient increased by increasing the distance of the Gurney flap from the airfoil escape edge at a 90-degree angle and 1.5%, as well as increasing the Reynolds number at a constant height of a Gurney flap.
H. Farzan, S.m. Jaafarian, M. Ameri,
Volume 20, Issue 5 (May 2020)
Abstract
The asphalt pavements are exposed to daily solar radiation; hence the asphalt pavements provide the remarkable potential to heat a working fluid such as water. Simple structure and ease of fabrication of asphalt solar collectors (ASCs) promise applicability and low-cost operation of this class of thermal collectors. The current experimental and theoretical investigation evaluates the performance, efficiency and dynamic of ASCs in real operating condition at Bam County, Kerman. In this research, to investigate the performance of ASCs, a 1.2m2 prototype was fabricated and its dynamics was monitored under 6 hours a day in two different flow rates of water. The results illustrate that increasing the flow rate of water to collector by 2 times improves the collector efficiency by 25%, while the difference in the inlet and outlet water temperatures decreases. Furthermore, by utilizing the experimental data, a theoretical approach was utilized to predict the performance of ASC in the other flow rates of water. The developed analytic approach has good consistency with the obtained experimental test. The analytic approach provides an effective method to estimate the performance of ASCs with appropriate accuracy, when the experimental results are unavailable.