Modares Mechanical Engineering

Modares Mechanical Engineering

A Systematic Approach to the Design, Optimization, and Fabrication of a Robotic Knee Exoskeleton for Post-Total Knee Arthroplasty Rehabilitation

Document Type : Original Article

Authors
1 1 Sharif University of Technology International Campus, Kish Island, Iran, Alfurat Al-Awsat Technical University, Alkufa, Iraq
2 Sharif University of Technology International Campus, Kish Island, Iran
10.48311/mme.2026.123268.83099
Abstract
Rehabilitation post-total knee arthroplasty (TKA) demands intensive physical therapy to restore joint functionality, and prevent joint stiffness. Conventional manual physiotherapy is labor intensive and costly, while multi joint whole leg exoskeletons introduce excessive complexity, high mass, and protracted fitting times ill suited for isolated joint recovery. This paper presents a systematic framework encompassing the design, finite element analysis driven optimization, and fabrication of a single degree of freedom robotic knee exoskeleton specifically intended for post TKA rehabilitation. Key design features, including sagittal plane flexion/extension, joint alignment compensation, low distal inertia, and state based impedance control, were distilled from a comprehensive synthesis of lower limb rehabilitation robotics literature. Coupled finite element modeling and Sobol-based global sensitivity analysis revealed that the link thickness and cross-sectional area emerged as the main factor controlling peak stress and deformation. The multi objective optimization strategy successfully decreased the peak von Mises stress under dynamic loading by 13.2%, attaining 143.9 MPa. In addition, structural deflection was reduced by 27% to 0.62 mm, and yielding the fatigue safety factor of 1.67 with an infinite operational life cycle. Furthermore, cuff limb interaction forces were reduced by 30% to 44.3 N, effectively mitigating the risk of soft tissue trauma. The final prototype achieved a total mass of 2.8 kg with a more proximal center of mass, substantially reducing rotational inertia and passive gravitational torque. The proposed prototype provides an optimized, lightweight robotic framework establishing the structural and mechatronic foundation required for subsequent clinical evaluation of progressive post-TKA knee mobilization.
Keywords
Subjects

[1] C. Vandepitte, L. Van Pachtenbeke, I. Van Herreweghe, R. K. Gupta, and N. M. Elkassabany, "Same day joint replacement surgery: Patient selection and perioperative management," Anesthesiol. Clin., vol. 40, no. 3, pp. 537–545, 2022. doi: 10.1016/j.anclin.2022.04.003.
[2] R. B. Salter, H. W. Hamilton, J. H. Wedge, M. Tile, I. P. Torode, S. W. O’Driscoll, J. J. Murnaghan, and J. H. Saringer, “Clinical application of basic research on continuous passive motion for disorders and injuries of synovial joints: A preliminary report of a feasibility study,” J. Orthop. Res., vol. 1, no. 3, pp. 325–342, 1984. doi: 10.1002/jor.1100010313.
[3] L. A. Bennett, S. C. Brearley, J. A. L. Hart, and M. J. Bailey, “A comparison of 2 continuous passive motion protocols after total knee arthroplasty: A controlled and randomized study,” J. Arthroplasty, vol. 20, no. 2, pp. 225–233, Feb. 2005. doi: 10.1016/j.arth.2004.08.009.
[4] R. N. Maniar, J. V. Baviskar, T. Singhi, and S. S. Rathi, “To use or not to use continuous passive motion post–total knee arthroplasty,” J. Arthroplasty, vol. 27, no. 2, pp. 193–200, Feb. 2012. doi: 10.1016/j.arth.2011.04.009.
[5] A. B. Imhoff, K. Beitzel, K. Stamer, E. Klein, and G. Mazzocca, Eds., Rehabilitation in Orthopedic Surgery. Berlin, Heidelberg, Germany: Springer Berlin Heidelberg, 2016. doi: 10.1007/978-3-662-49149-2.
[6] Y. Sankai, “HAL: Hybrid assistive limb based on cybernics,” in Robotics Research, M. Kaneko and Y. Nakamura, Eds. Berlin, Heidelberg, Germany: Springer Berlin Heidelberg, 2010, pp. 25–34. doi: 10.1007/978-3-642-14743-2_3.
[7] EksoHealth | Ekso Bionics. [Online]. Available: https://eksobionics.com/eksohealth/products/
[8] S. A. Kolakowsky-Hayner, J. Crew, S. Moran, and A. Shah, “Safety and feasibility of using the EksoTM bionic exoskeleton to aid ambulation after spinal cord injury,” J. Spine, vol. 4, no. 3, 2013. doi: 10.1080/10790268.2019.1671076.
[9] R. Little and R. A. Irving, “Self contained powered exoskeleton walker for a disabled user,” U.S. Patent 2011/0066088 A1, Mar. 17, 2011.
[10] M. A. Beirne, K. Nedley, S. Wallis, and G. E. Francisco, “A treatment proposal with lower extremity robotic devices: Performance of postural analysis and determination of exercises using the REX robot,” TIRR Memorial Hermann – Rehabilitation & Research.
[11] R. Bogue, “Exoskeletons and robotic prosthetics: A review of recent developments,” Ind. Robot, vol. 36, no. 5, pp. 421–427, Aug. 2009. doi: 10.1108/01439910910980141.
[12] K. Raab, K. Krakow, F. Tripp, and M. Jung, “Effects of training with the ReWalk exoskeleton on quality of life in incomplete spinal cord injury: A single case study,” Spinal Cord Ser. Cases, vol. 2, p. 15025, 2016. doi: 10.1038/scsandc.2015.25.
[13] Indego – Powering People Forward | Parker Indego. [Online]. Available: http://www.indego.com/indego/en/home.
[14] PHOENIX Medical Exoskeleton | suitX. [Online]. Available: https://www.suitx.com/phoenix-medical-exoskeleton
[15] B. Celebi, M. Yalcin, and V. Patoglu, “AssistOn-Knee: A self-aligning knee exoskeleton,” in 2013 IEEE/RSJ Int. Conf. Intell. Robots Syst. (IROS), Tokyo, Japan, Nov. 2013, pp. 996–1002. doi: 10.1109/IROS.2013.6696472.
[16] A. Taherifar, G. Vossoughi, and A. Selk Ghafari, "Identification and torque control of series elastic actuator of lower limb extremity exoskeleton," Modares Mech. Eng., vol. 17, no. 8, pp. 1–8, 2017. Dor: 20.1001.1.10275940.1396.17.8.38.2
[17] V. A. D. Cai, P. Bidaud, T. T. Le, A. Ibanez, and X. T. Phan, “In search of transparency for lower limb exoskeleton devices with a new mechanical design and a robust gait phases detection method,” in 2015 IEEE Int. Conf. Robot. Biomim. (ROBIO), Zhuhai, China, Dec. 2015, pp. 1151–1156. doi: 10.1109/ROBIO.2015.7418927.
[18] M. Wehner et al., “A lightweight soft exosuit for gait assistance,” in 2013 IEEE Int. Conf. Robot. Autom. (ICRA), Karlsruhe, Germany, May 2013, pp. 3362–3369. doi: 10.1109/ICRA.2013.6631046.
[19] S. Hosseinpour Malakouti and S. Ozgoli, "Design, control, and experimental evaluation of a lightweight active knee–ankle–foot orthosis with adjustable knee motion for mobility assistance after spinal cord injury," Modares Mech. Eng., vol. 26, no. 4, pp. 261–269, 2026. doi: 10.48311/mme.2026.118299.82908.
[20] R. Wilmart, E. Garone, and B. Innocenti, “The use of robotics devices in knee rehabilitation: A critical review,” Muscle Ligaments Tendons J., vol. 9, no. 1, pp. 21–48, 2019. doi: 10.32098/mltj.01.2019.07.
[21] S. Hesse, A. Waldner, and C. Tomelleri, “Innovative gait robot for the repetitive practice of floor walking and stair climbing up and down in stroke patients,” J. Neuroeng. Rehabil., vol. 7, p. 30, Jun. 2010. doi: 10.1186/1743-0003-7-30.
[22] G. Colombo, M. Joerg, R. Schreier, and V. Dietz, "Treadmill training of paraplegic patients using a robotic orthosis," J. Rehabil. Res. Dev., vol. 37, no. 6, pp. 693–700, Nov. 2000. PMID: 11321005.
[23] S. Freivogel, J. Mehrholz, T. Husak-Sotomayor, and D. Schmalohr, "Gait training with the newly developed 'LokoHelp'-system is feasible for non-ambulatory patients after stroke, spinal cord and brain injury. A feasibility study," Brain Injury, vol. 22, no. 7–8, pp. 625–632, Jul. 2008. doi: 10.1080/02699050801941771.
[24] S. K. Banala, S. K. Agrawal, and J. P. Scholz, "Active leg exoskeleton (ALEX) for gait rehabilitation of motor-impaired patients," in Proc. 10th IEEE Int. Conf. Rehabil. Robot. (ICORR), Noordwijk, The Netherlands, Jun. 2007, pp. 401–407. doi: 10.1109/ICORR.2007.4428456.
[25] J. F. Veneman, R. Kruidhof, E. E. G. Hekman, R. Ekkelenkamp, E. H. F. Van Asseldonk, and H. Van Der Kooij, "Design and evaluation of the LOPES exoskeleton robot for interactive gait rehabilitation," IEEE Trans. Neural Syst. Rehabil. Eng., vol. 15, no. 3, pp. 379–386, Sep. 2007. doi: 10.1109/TNSRE.2007.903919.
[26] S. Hesse, D. Uhlenbrock, C. Werner, and A. Bardeleben, "A mechanized gait trainer for restoring gait in nonambulatory subjects," Arch. Phys. Med. Rehabil., vol. 81, no. 9, pp. 1158–1161, Sep. 2000. doi: 10.1053/apmr.2000.6280.
[27] H. Schmidt, S. Hesse, R. Bernhardt, and J. Krüger, "HapticWalker—a novel haptic foot device," ACM Trans. Appl. Percept., vol. 2, no. 2, pp. 166–180, Apr. 2005. doi: 10.1145/1060581.1060589.
[28] H. Yano, S. Tamefusa, N. Tanaka, H. Saitou and H. Iwata, "Gait rehabilitation system for stair climbing and descending," 2010 IEEE Haptics Symposium, Waltham, MA, USA, 2010, pp. 393-400, doi: 10.1109/HAPTIC.2010.5444627.
[29] M. Peshkin, D. A. Brown, J. J. Santos-Munne, A. Makhlin, E. Lewis, J. E. Colgate, J. Patton, and D. Schwandt, "KineAssist: A robotic overground gait and balance training device," in Proc. 9th IEEE Int. Conf. Rehabil. Robot. (ICORR), Chicago, IL, USA, Jun. 2005, pp. 241–246. doi: 10.1109/ICORR.2005.1501094.
[30] M. Bouri, Y. Stauffer, C. Schmitt, Y. Allemand, S. Gnemmi, R. Clavel, P. Metrailler, and R. Brodard, "The WalkTrainer: A robotic system for walking rehabilitation," in Proc. IEEE Int. Conf. Robot. Biomim. (ROBIO), Kunming, China, Dec. 2006, pp. 1616–1621. doi: 10.1109/ROBIO.2006.340186.
[31] H. Kawamoto and Y. Sankai, "Power assist system HAL-3 for gait disorder person," in Computers Helping People with Special Needs, K. Miesenberger, J. Klaus, and W. Zagler, Eds., (Lecture Notes in Computer Science, vol. 2398), Berlin, Heidelberg: Springer, 2002, pp. 196–203. doi: 10.1007/3-540-45491-8_43.
[32] H. Kawamoto, T. Hayashi, T. Sakurai, K. Eguchi, and Y. Sankai, "Development of single leg version of HAL for hemiplegia," in Proc. 31st Annu. Int. Conf. IEEE Eng. Med. Biol. Soc. (EMBC), Minneapolis, MN, USA, Sep. 2009, pp. 5038–5043. doi: 10.1109/IEMBS.2009.5333698.
[33] H. Schmidt, "HapticWalker—A novel haptic device for walking simulation," in Proc. EuroHaptics Conf., Munich, Germany, Jun. 2004, pp. 60–67.
[34] M. Girone, G. Burdea, M. Bouzit, V. Popescu, and J. E. Deutsch, "Stewart platform-based system for ankle telerehabilitation," Auton. Robots, vol. 10, no. 2, pp. 203–212, Mar. 2001. doi: 10.1023/A:1008938121020.
[35] J. Nikitczuk, B. Weinberg, P. K. Canavan, and C. Mavroidis, "Active knee rehabilitation orthotic device with variable damping characteristics implemented via an electrorheological fluid," IEEE/ASME Trans. Mechatronics, vol. 15, no. 6, pp. 952–960, Dec. 2010. doi: 10.1109/TMECH.2009.2036170.
[36] E. Reznick, K. R. Embry, R. Neuman, E. Bolívar-Nieto, N. P. Fey, and R. D. Gregg, "Lower-limb kinematics and kinetics during continuously varying human locomotion," Sci. Data, vol. 8, p. 282, 2021. doi: 10.1038/s41597-021-01057-9.
[37] A. Asker, M. Omar, J. Zhang, K. Wang, R. Li, and S. Xie, "Optimum design of polycentric knee hinges based on analysis of knee-exoskeleton closed kinematic chain," Proc. Inst. Mech. Eng. C, vol. 239, no. 11, pp. 4085–4098, 2025. doi: 10.1177/09544062251313926.
[38] S. Patrick, N. Anil Kumar, and P. Hur, "Evaluating knee mechanisms for assistive devices," Front. Neurorobot., vol. 16, Art. ID 790070, May 2022. doi: 10.3389/fnbot.2022.790070.
[39] R. C. Browning, J. R. Modica, R. Kram, and A. Goswami, "The effects of adding mass to the legs on the energetics and biomechanics of walking," Med. Sci. Sports Exerc., vol. 39, no. 3, pp. 515–525, Mar. 2007. doi: 10.1249/mss.0b013e31802b3562.
[40] G. M. Bryan, P. W. Franks, S. C. Klein, R. J. Peuchen, and S. H. Collins, "A hip-knee-ankle exoskeleton emulator for studying gait assistance," Int. J. Robot. Res., vol. 40, pp. 722–746, 2020. doi: 10.1177/0278364920961452.
[41] M. S. Ashrafi, M. Nazari, N. Sepehry, M. Mahdizadeh Rokhi, P. Samimi, and M. Attarchi, "Design and implementation of a fuzzy output feedback assistive controller for a series-elastic-actuator-driven knee exoskeleton," Modares Mech. Eng., vol. 22, no. 8, pp. 541–553, 2022. doi: 10.52547/mme.22.8.541.
[42] T. Kikuchi, K. Oda, and J. Furusho, "Leg-robot for demonstration of spastic movements of brain-injured patients with compact magnetorheological fluid clutch," Adv. Robot., vol. 24, no. 16, pp. 671–686, 2010. doi: 10.1163/016918610X496621.
[43] J. E. Pratt, B. T. Krupp, C. J. Morse, and S. H. Collins, "The RoboKnee: An exoskeleton for enhancing strength and endurance during walking," in Proc. IEEE Int. Conf. Robot. Autom. (ICRA), New Orleans, LA, USA, May 2004, vol. 3, pp. 2430–2435. doi: 10.1109/ROBOT.2004.1307561.
[44] M. K. Shepherd and E. J. Rouse, "Design and validation of a torque-controllable knee exoskeleton for sit-to-stand assistance," IEEE/ASME Trans. Mechatronics, vol. 22, no. 4, pp. 1695–1704, Aug. 2017. doi: 10.1109/TMECH.2017.2704588.
[45] S. Mazzoleni, A. Focacci, M. Franceschini, A. Waldner, C. Spagnuolo, E. Battini, and D. Bonaiuti, "Robot-assisted end-effector-based gait training in chronic stroke patients: A multicentric uncontrolled observational retrospective clinical study," NeuroRehabilitation, vol. 40, no. 4, pp. 483–492, 2017. doi: 10.3233/NRE-161435.
[46] J. L. Emken, S. J. Harkema, J. A. Beres-Jones, C. K. Ferreira, and D. J. Reinkensmeyer, "Feasibility of manual teach-and-replay and continuous impedance shaping for robotic locomotor training following spinal cord injury," IEEE Trans. Biomed. Eng., vol. 55, no. 1, pp. 322–334, Jan. 2008. doi: 10.1109/TBME.2007.910683.
[47] P. W. Franks, G. M. Bryan, R. M. Martin, R. Reyes, A. C. Lakmazaheri, and S. H. Collins, "Comparing optimized exoskeleton assistance of the hip, knee, and ankle in single and multi-joint configurations," Wearable Technol., vol. 2, p. e16, 2021. doi: 10.1017/wtc.2021.14.
[48] M. B. Näf, K. Junius, M. Rossini, C. Rodriguez-Guerrero, B. Vanderborght, and D. Lefeber, "Misalignment compensation for full human-exoskeleton kinematic compatibility: State of the art and evaluation," ASME Appl. Mech. Rev., vol. 70, no. 5, Art. no. 050802, Sep. 2018, doi: 10.1115/1.4042523.
[49] V. A. D. Cai, P. Bidaud, V. Hayward, F. Gosselin and E. Desailly, "Self-adjusting, isostatic exoskeleton for the human knee joint," 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Boston, MA, USA, 2011, pp. 612-618, doi: 10.1109/IEMBS.2011.6090136.
[50] Y. Niu, Z. Song, and J. Dai, "Kinematic analysis and optimization of a planar parallel compliant mechanism for self-alignment knee exoskeleton," Mechanical Sciences, vol. 9, no. 2, pp. 405–416, 2018. doi: 10.5194/ms-9-405-2018.
[51] A. Schiele and F. C. T. van der Helm, "Influence of attachment pressure and kinematic configuration on pHRI with wearable robots," Applied Bionics and Biomechanics, vol. 6, no. 2, pp. 157–173, 2009, doi: 10.1080/11762320902879961.
[52] C. C. Norkin and D. J. White, Measurement of Joint Motion: A Guide to Goniometry, 5th ed. Philadelphia, PA: F. A. Davis Company, 2017.
[53] A. Nasr, K. Inkol, and J. McPhee, "Safety in wearable robotic exoskeletons: Design, control, and testing guidelines," J. Mech. Robot., vol. 17, no. 5, pp. 1–13, 2025. doi: 10.1115/1.4066900.
[54] D. Karibzhanova, A. Niyetkaliyev, A. R. Khawaja, A. Zhaisanbek, Zeeshan, A. Utepbergen, P. K. Jamwal, K. Ozhikenov, A. Ozhikenova, Z. Alimbayeva, Z. Bigaliyeva, L. Bazarbay, and S. Didar, "State-of-the-art knee exoskeleton for gait assistance and rehabilitation: Systematic review," JMIR Rehabil. Assist. Technol., vol. 13, Art. no. e94916, 2026, doi: 10.2196/94916.
[55] P. M. Anderson, T. Heinz, E. Scholmann, A. Eidmann, J. Arnholdt, M. Rudert, B. M. Holzapfel, and I. Stratos, "Efficacy of post-operative partial weight-bearing after total knee arthroplasty - a prospective observational trial," Int. Orthop., vol. 47, no. 9, pp. 2189–2195, Sep. 2023, doi: 10.1007/s00264-023-05783-0.
[56] X. Wan, Y. Liu, Y. Akiyama and Y. Yamada, "Monitoring Contact Behavior During Assisted Walking with a Lower Limb Exoskeleton," in IEEE Transactions on Neural Systems and Rehabilitation Engineering, vol. 28, no. 4, pp. 869-877, April 2020, doi: 10.1109/TNSRE.2020.2979986.
[57] Y. Akiyama, Y. Yamada, and S. Okamoto, "Interaction forces beneath cuffs of physical assistant robots and their motion-based estimation," Adv. Robot., vol. 29, no. 20, pp. 1315–1329, 2015, doi: 10.1080/01691864.2015.1055799.
[58] D. Shi, W. Zhang, W. Zhang, and X. Ding, "A review on lower limb rehabilitation exoskeleton robots," Chin. J. Mech. Eng. (Engl. Ed.), vol. 32, no. 1, 2019. doi: 10.1186/s10033-019-0389-8.
[59] J. K. Burgess, G. C. Weibel, and D. A. Brown, "Overground walking speed changes when subjected to body weight support conditions for nonimpaired and post stroke individuals," J. NeuroEng. Rehabil., vol. 7, no. 1, p. 6, 2010. doi: 10.1186/1743-0003-7-6.
[60] I. Díaz, J. J. Gil, and E. Sánchez, "Lower-limb robotic rehabilitation: Literature review and challenges," J. Robot., vol. 2011, Art. ID 759764, 2011. doi: 10.1155/2011/759764.
[61] I. M. Dávila Castrodad, T. M. Recai, M. M. Abraham, J. I. Etcheson, N. S. Mohamed, A. Edalatpour, and R. E. Delanois, "Rehabilitation protocols following total knee arthroplasty: A review of study designs and outcome measures," Ann. Transl. Med., vol. 7, no. Suppl. 7, p. S255, Oct. 2019. doi: 10.21037/atm.2019.08.15.